REQUEST SERVICE

+62 21 54376065

 

 

   
Home / Drives / AC Drives / Close Loop Vector

  MICNO KE 200 SERIES  



KE200 high performance vector control inverter 

KE200 focus on high performance using experience
KE200 adopts optimized vector control technology, control motor excitation current and torque current directly, which has different kinds of advanced functions, such as zero-servo, slip compensation, torque compensation, speed control, mute control, accurate parameter identification ability, etc. KE200 can drive any brand motor in a high control level.
Integrated with vector control (with/without PG), V/f control (with/without PG), KE200 is widely used in precision machinery control and several motors driven applications.




  PRODUCT REVIEW  

KE200 high performance vector control inverter

KE200 focus on high performance using experience
KE200 adopts optimized vector control technology, control motor excitation current and torque current directly, which has different kinds of advanced functions, such as zero-servo, slip compensation, torque compensation, speed control, mute control, accurate parameter identification ability, etc. KE200 can drive any brand motor in a high control level.
Integrated with vector control (with/without PG), V/f control (with/without PG), KE200 is widely used in precision machinery control and several motors driven applications.
 
Specifications of KE600 are as follows.






Input Input voltage

3AC 220V±15%   3AC 380V±15%

Input frequency

47~63Hz

   
 
Output Output voltage

0~Rated voltage

Output frequency

0~400Hz

   
 

Control

Feature

Control mode

V/f control (with/without PG), Sensorless vector control, Close loop vector control

Operation command mode

Digital setting, analog setting, serial communication setting, multi-step speed setting, PID setting, etc. These frequency settings can be combinated & switched in various modes.

Overload capacity

150% 60s, 180% 10s, 200% 3s.

Starting torque

0Hz/150% (VC); 1Hz/150% (SVC)

Speed adjustment range

1:1000 (VC); 1:100 (SVC)

Speed control precision

±0.2% (SVC); ±0.02% (VC)

Speed response

<20ms (SVC); <3.5ms (VC)

Torque limit

Available (parameter setting 4 modes)

Torque response

20Hz (SVC); 40Hz (VC)

Frequency control range

0.1~400Hz

Frequency accuracy

Digital command: ±0.01% (-10℃~40℃)
Analog command: ±0.1% (25℃±10℃)

Setting frequency resolution

Digital keypad command: ±0.01Hz

Output frequency resolution

Analog command: ±0.03Hz/60Hz (11bit + code) 0.01Hz

Frequency setting signal

-10V~10V, 0~10V (20kΩ), 4~20mA

ACC/DEC mode

0.01s~6000.0s (ACC time and DEC time are set separately, four kinds of ACC/DEC time)

Braking torque

20% (150% when equipped with braking resistor)

V/f curve

15 fixed types and random V/f curve setting

   
 
Protection Function Motor overload protection

Protect by hot electric 

Instantaneous over voltage

Motor coast to stop when the inverter outputs 200% rated current

Blown fuse protection

Motor coast to stop

Overload

Motor coast to stop when the inverter outputs 150% rated current for 1 minute (150% 2 minutes can be customized)

Over voltage

Stop when main circuit voltage>410V(820V)*1

Under voltage

Stop when main circuit voltage<190V(380V)*1

Instantaneous power off compensation

Set the motor stops in 2 sec when power off in the running motor, then the motor runs continuously

Radiator overheat 

Protect by temperature switch

Stall protection

ACC and DEC, stall protection when running

Ground fault

Protect by circuit

Charging protection

No display if DC voltage of main circuit below 50V

   
 
Terminals Input terminals

DI: 8 on-off inputs (2 fixed)
3 AI: 2 programmable. AI1: voltage 0~10V
A12: voltage -10~10V or current 4~20mA

Output terminals

2 programmable open collector output
1 relay output (normally open)
1 programmable relay output
2 programmable analog output: -10~10V

Communication terminal*2

Offer RS485 communication interface, support MODBUS-RTU communication protocol 

   
 

Enviorment

Limit

Ambient temperature

-10℃~40℃, derated 4% when the temperature rise by each1℃ (40℃~50 ℃). 

Humidity

90%RH or less (non-condensing)

Altitude

≤1000M: output rated power, >1000M: output derated

Storage temperature

-20℃~60℃

Storage atmosphere

Indoor, without direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip, salt, vibration, etc.